Fieldpiece S365 - Charging Jacket for TXV Systems Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Instrumentos de medición Fieldpiece S365 - Charging Jacket for TXV Systems. Fieldpiece S365 - Charging Jacket for TXV Systems User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 2
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
WARNINGS
Only use on TXV systems using
either R410A or R22.
Ensure the system is powered
OFF before installing the Charg-
ing Jacket.
Severe injury can occur if the fan
turns ON before hooks are se-
curely fastened towards the top
of the condenser.
Wear eye protection.
Only use when the ambient dry
bulb temperature is between
37°F and 70°F (3°C to 21°C.)
Using outside of this range can
damage the air conditioner/heat
pump.
Head pressure of the system
needs to remain within the
following safe ranges to avoid
damage to the compressor or
other equipment:
R22: 55psig to 300psig
R410A: 97psig to 500psig
Stop the system if the head pres-
sure approaches these limits.
Description
HVACR technicians typically
cannot charge a cooling system in
cold weather. The cold temperature
removes too much heat from the
condenser coils.
The Charging Jacket from Fieldpiece
Instruments allow you to charge a TXV
system when ambient temperatures
are between 70°F and 37°F.
It works by restricting the fan outlet
of the condenser, in eect raising the
temperature within the condsenser.
This is a more eective method than
blocking the incoming air to the
condenser coil .
Look professional and increase
your amount of possible jobs. No
more trash bags or cardboard! Do it
the right way.
Maintenance
Hand wash with cold water and
mild detergent if needed and let air
dry. Do not machine wash or dry.
Fieldpiece
Charging Jacket
OPERATOR'S MANUAL
Model S365
How to Use
The Winter Charge Setup may
only be used for equipment for which
the air conditioning manufacturers
approve the use of the Winter
Charge Setup. Refer to (California’s)
Energy Commissions website for
the list of split system air condition
units approved by the manufacturers
to use the Winter Charge Setup. In
addition to the requirements of this
document, manufacturers may issue
additional instructions/clarication
for the equipment and procedures to
be used to conduct the Winter Charge
Setup. These additional instruction/
clarifications are also available on
the (California) Energy Commission
website.
-- California Title 24 2013 Edition
Setup
1 Power down the system.
2 Install Charging Jacket:
A. Tighten Bungie Cinch around top
of condenser fan cage making sure
not to block the airow inlet (sides.)
B. Fasten hooks securely so that the
the fan does not eject the Charging
Jacket when the system starts.
C. Always start with the top open,
then tighten the restriction string
to restrict airow as needed.
3 Make sure people and animals are
clear of the condenser, then start
the system. If using on a heat pump,
set it to cooling mode.
4 Carefully adjust the restriction
of the Charging Jacket until the
difference between the high
side and the low side pressures
is between 160psi and 220psi
(R410A) or 100psi and 145psi (R22).
Restricting airflow increases the
pressure dierence.
Check Refrigerant Charge
5 Once the system is within the
pressure dierence range, allow
the system to stabilize for 15
minutes.
6 Calculate Actual Subcooling.
(Tcondenser, saturation - T liquid line)
If your subcooling is more
than three degrees less than the
target subcooling, then you are
undercharged. (continued)
!
!
!
!
!
!
!
!
!
!
!
BUNGIE CINCH
RESTRICTION STRING
Vista de pagina 0
1 2

Indice de contenidos

Pagina 1 - Fieldpiece

WARNINGSOnly use on TXV systems using either R410A or R22.Ensure the system is powered OFF before installing the Charg-ing Jacket. Severe injury

Pagina 2 - More Products

If your subcooling is more than one degree over the target subcooling, you are overcharged. EXAMPLESTarget subcooling = 12°F and your measured subcoo

Comentarios a estos manuales

Sin comentarios

Samsung RW33EBSS podręczniki

Instrukcje obsługi i podręczniki użytkownika dla odtwarzacze CD Samsung RW33EBSS.
Dostarczamy pdf podręczników Samsung RW33EBSS do pobrania za darmo według typów dokumentów:






Więcej produktów i instrukcji dla odtwarzacze CD Samsung

Modele Rodzaj dokumentu
MXHS9000 Instrukcja Użytkownika   Samsung MXHS9000 User's Manual, 30 strony
MAX-VB630 Instrukcja Użytkownika   Samsung MAX-VB630 User manual, 30 strony
YP-NDU64S Instrukcja Użytkownika   Samsung YP-NDU64S User manual, 16 strony
MM-J5 Instrukcja Użytkownika   Samsung MM-J5 User manual, 12 strony
MAX-VS940 Instrukcja Użytkownika   Samsung MAX-VS940 User manual, 28 strony
MAX-VB450 Instrukcja Użytkownika   Samsung MAX-VB450 User manual, 28 strony
MM-T6 Instrukcja Użytkownika   Samsung MM-T6 User manual, 13 strony
MAXVL85FH/UMG Instrukcja Użytkownika   Samsung MAX-VL85 User manual, 30 strony
MCD-MP67 Instrukcja Użytkownika   Samsung MCD-MP67 User's Manual, 27 strony
B450 Instrukcja Użytkownika   Samsung MAX-B420 Instrukcja obsługi, 25 strony
MM-G35 Instrukcja Użytkownika   Samsung MM-G35 User manual, 26 strony
MAX-ZL65 Instrukcja Użytkownika   Samsung MAX-ZL65 User manual, 27 strony
MAX-VS720 Instrukcja Użytkownika   Samsung MAX-VS720 User manual, 28 strony
MAX-T35 Instrukcja Użytkownika   Samsung MAX-T35 User manual, 14 strony
MM-C330 Instrukcja Użytkownika   Samsung MM-C330 User manual, 27 strony
MCD-HM200 Instrukcja Użytkownika   Samsung MCD-HM200 User's Manual, 18 strony
MX-JS9500/ZA Instrukcja Obsługi   Samsung MX-JS9500/ZA Product manual, 34 strony
MM-B3/B4 Instrukcja Użytkownika   Samsung MM-B3/B4 User's Manual, 12 strony
MAX-VS530 Instrukcja Użytkownika   Samsung MAX-VS530 User manual, 28 strony
MAX-900 Instrukcja Użytkownika   Samsung MAX-900 User manual, 12 strony